A simple definition of SPR would be "a phenomenon in which the electron cloud (collective) on the surface of a metal film and an external stimulus (light energy) resonate under specific environmental (conditions)." This sentence contains a lot of physics terminology and is expressed concisely, making it difficult to understand even after reading it several times.

While observing the above image, let me explain a phenomenon that we can directly see with our own eyes.

Let's consider the yellow gold chip in the above image as a mirror. If we shine a laser beam onto the mirror (or incident it) from any angle, the light will be reflected. This is a commonsense phenomenon. However, if we attach a cylindrical lens called a prism in the direction that the light enters the mirror, as shown in the image, and incident the light while changing the angle of incidence from 0 to 90 degrees, we can observe a phenomenon where the light disappears at a certain angle, as if the incident light has been absorbed by the gold chip. This phenomenon is called the SPR phenomenon.

The device that utilizes this phenomenon is called an SPR biosensor. Such devices, filled with physical terminology, are mainly used in the field of biology/chemistry today.

When researchers obtain data using an SPR biosensor, understanding the principles of the SPR phenomenon and sensing is important to obtain better results and to interpret them correctly. Therefore, knowing the basic principles of the SPR phenomenon and sensing is important.

There are many different sensing methods that utilize SPR phenomenon. To avoid confusion, I will focus on the SPR sensing principle of the Kretschmann configuration (angle-interrogation) SPR method. Kretschmann was one of the initial researchers in SPR and the configuration shown in the above image is his invention. While the first person to publish a paper on SPR was Wood, Kretschmann is better known, because most current SPR devices follow his method. This method has the advantage of being stable and achieving high sensitivity in obtaining results.


조회수 6회댓글 0개
iclubio-logo-b.png

since 2017

About us

Products

Support

Instruments

Academic

Consumables

주소

본사 

경기 안산시 상록구 해양3로 15 그랑시티시그니처타워 711호

장치 팩토리

경기 안산시 상록구 해양3로 15 그랑시티시그니처타워 712호

분석서비스센터

경기 안산시 상록구 해양3로 15 그랑시티시그니처타워 713

Services

Analysis service

Rental service

문의

대표번호 031-406-6180

분석문의 031-406-6181

장치문의 031-406-6182

팩스 031-406-6186

Copyright © ICLUEBIO Co., Ltd. All rights reserved.

본 웹사이트에 포함된 정보는 광범위한 이용자를 대상으로 합니다. 그렇기 때문에, 귀하의 국가에서 접근 가능하거나 유효하지 않은 제품 설명이나 정보를 포함하고 있을 수도 있습니다. 저희는 귀하의 국가의 법적 절차 규칙, 등록 또는 용법을 준수하지 않는 정보의 접근 가능성에 대하여 책임을 부담하지 않음을 알려 드립니다.

bottom of page